Home
About UsAbout ZhijuCore ValuesTeam SpiritHonors & CertificatesMilestones
Business & ServicesBusiness OverviewTechnology Transfer
Results & CasesResults Overview
Works Library Technology Transfer
Zhiju VoiceCompany NewsIndustry News
Contact UsContact InformationCareers

‹ Back to Works Library / Heart & Brain

HEART & BRAIN · themed illustration set (5 pieces)

Transcranial magnetic stimulation illustrations

Year not recordedStatic illustration

Magnetic-stimulation scenes: treatment, coil-and-brain diagrams and the treatment room.

Transcranial magnetic stimulation illustrations

Versions & components (5 confirmed files; duplicates within the same work counted once)

Versions, components and composite layouts of the same work; click to enlarge.

TMS illustrations · another treatment scene
another treatment scene (source file F047)
TMS illustrations · coil and brain
coil and brain diagram (source file F061)
TMS illustrations · treatment room
treatment room (source file F167)
TMS illustrations · 3D stimulation sketch
3D brain stimulation sketch (source file F168)
themed illustration set (5 pieces)Heart & BrainYear not recorded Created by the Zhiju team · Click image to enlarge
In 30 Seconds

TMS-themed illustrations: treatment chair, coil-to-brain placement, treatment room and a 3D stimulation sketch. Topically related to the team's deep magnetic stimulation research; archived per composition without assuming an order of versions.

The Story Behind the Image

Paper abstract (original)

Introduction Sleep deprivation (SD) significantly disrupts the homeostasis of the cardiac-brain axis, yet the neuromodulation effects of deep magnetic stimulation (DMS), a non-invasive and safe method, remain poorly understood. Methods Sixty healthy adult males were recruited for a 36-h SD study, they were assigned to the DMS group or the control group according to their individual willing. All individuals underwent heart sound measurements and functional magnetic resonance imaging scans at the experiment's onset and terminal points. During the recovery sleep phase, DMS was applied twice for 30 min before sleep onset and upon awakening to the individuals in the DMS group. Two-factor analysis was used to disclose the changes in two status and intervention effect in groups, along with Spearman rank correlation analysis to assess the correlation between brain activity and heart activity, the linear regression analysis was performed to explore the effect of DMS on brain regions to regulated the heart activity. Additionally, bootstrapping analysis was employed to verify the mediation effect. Results The results indicated that the DMS group cardiac cycle duration was 0.81 ± 0.04 s, CON group was 0.80 ± 0.03 s, DMS presented a prolong effect ( F = 0.32, p = 0.02), and all heart frequency and intensity indexes value were lower than CON group ( p < 0.01). Two-factor analysis demonstrated the significant differences in the left insula and orbitofrontal inferior gyrus, which DC_Weight (0.25) value were lower 0.50 ( p < 0.01), 0.42 ( p < 0.01) after DMS. Furthermore, the correlation analysis confirmed that the negative association between the left orbital inferior frontal and left insula with the heart sound index ( p < 0.05), such as Δ left orbital inferior frontal were negatively correlated with Δ Systolic_intensity (rho = −0.33, p < 0.05), Δ Diastolic_intensity (rho = −0.41, p < 0.05), Δ S1_intensity (rho = −0.36, p < 0.05), and Δ S2_intensity (rho = −0.43, p < 0.05). Δ Left insula was negatively correlated with Δ Diastolic_intensity (rho = −0.36, p < 0.05), Δ S1_intensity (rho = −0.33, p < 0.05), and Δ S2_intensity (rho = −0.36, p < 0.05). Mediated effect analysis showed that DMS affected S2_intensity by intervening in brain regions. Conclusion These findings suggest a causal effect on the cardiac-brain axis following 36 h of SD. The non-invasive intervention of DMS effectively regulates both brain and heart functions after SD, promoting homeostatic balance. The DMS can affect the cardiac-brain axis, offering a means to restore balance following extended periods of SD.

Scope note Reference images with third-party device brands are not included or published.

CONTACT

Want your research illustrated too?

Explore our medical illustration services, or simply tell us what you need.

Contact Us

or call us directly at 028-6744 0718